• Quick and easy-to-install modular construction.
  • Flexible panel sizes ensuring efficient space utilization.
  • Optimal temperature management, with a choice of low-energy consuming, unitary or remote refrigeration system.
  • Refrigerator (+1/+40C) and Freezer (-18/-250C) and many more temperatures available.
  • Aesthetically designed flush doors.
  • Panel joints sealed with PVC gaskets, making routine cleaning easy and eliminating moisture penetration.
  • Reliable, warranty and post-warranty support available in several locations across India.
  • Scale drawings for approval and sign-off before construction begins.

 

 

Model
No.
Refrigeration
Capacity
BTU/Hr.
Temp.
Range
(C)
Loading
Temp.
(C)
Max.
Loading
kgs./Day
Max.
Room
Volume
(CFT)
Max.
Room
Area with
8’Ht.
(Sq.Ft.)
Ambient
(C)
Power
Consu-
mption
(kw)
Power
Supply
(V/Ph/Hz)
Defrosting Approx.
weight
(Kgs)
CH-8 8000 2
to 6
30 280 512 64 38
to 42
1.6 230/1/50 Off-cycle 70
CH-12 12000 2
to 6
30 540 960 120 38
to 42
2.0 230/1/50 Off-cycle 90
CH-15 15000 2
to 6
30 770 1360 170 38
to 42
2.5 230/1/50 Off-cycle 110
CH-19 19000 2
to 6
30 1000 1800 225 38
to 42
3.0 400/3/50 Off-cycle 150
CH-21 21000 2
to 6
30 1200 2080 260 38
to 42
3.4 400/3/50 Off-cycle 150
CH-36 36000 2
to 6
30 2200 3800 475 38
to 42
5.3 400/3/50 Off-cycle 170
CH-41 41000 2
to 6
30 2600 4520 565 38
to 42
5.7 400/3/50 Off-cycle 180
CL-4 4000 -20
to-23
-10 160 280 35 38
to 42
1.5 230/1/50 Electric 78
CL-6 6000 -20
to-23
-10 280 512 64 38
to 42
2.0 400/1/50 Electric 85
CL-10 10000 -20
to-23
-10 570 1000 125 38
to 42
3.6 400/3/50 Electric 110
CL-14 14000 -20
to-23
-10 900 1600 200 38
to 42
4.7 400/3/50 Electric 130
CL-19 19000 -20
to-23
-10 1400 2520 315 38
to 42
7.3 400/3/50 Electric 185
CL-23 23000 -20
to-23
-10 2000 3520 440 38
to 42
9.1 400/3/50 Electric 200
CPL-6 6000 -20
to-23
-10 280 512 64 38
to 42
2.2 400/3/50 Electric 80
CPL-9 9000 -20
to-23
-10 500 920 115 38
to 42
3.8 400/3/50 Electric 105

 

For specific model requirements please contact us.